3. Shock jitter on thick paper
Symptom Shock jitter on thick paper
Cause
Vibration of the ITB caused by either of the following:
1. Shock generated when the leading edge enters the nip of the ITB
2. Shock generated when the trailing edge exits the nip of the ITB and
Action
Depending on the two different causes, the following actions will reduce the
chances of shock jitters:
1. Enlarge the gap between the ITB and the PTR by specifying "Small
2. Shorten PTR release timing interval by changing SP1022-002 "Fine
Note: The default value of SP1022-002 was modified in the following Engine
Image
RTB #
RD074029 or newer
Note: The effect of the countermeasure will vary depending on the unit.
T
echnical
and the PTR
the PTR
Gap" for "Custom Paper Advanced Settings: 43 Adjust Gap of Paper
Transfer:"
Adj LEdge: Thick2" Default : -70 to -120.
firmware versions:
Copier: Version 1.60:04 (D0745404G)
Printer: Version 1.60:04 (M0445404E)