SC41x and/or the result of Process Control (SP3012) indicates error code "15"
Chances of this problem are higher when running the machine in a high humidity
environment in a cold-start, for example, Monday mornings or after lunch breaks.
Cause
 Potential Sensor Probe Dirty
 Potential Sensor Harness disconnected
 Potential Sensor Relay Board defective
 Potential Sensor Defective