Model:
Taurus-C1/P1
Subject:
Part for Charge Roller Lever Replacement
From:
PPCS Section, CIP Product Quality Management Dept.
Classification:
SYMPTOM
The Charge Roller Lever becomes damaged, requiring the replacement of the entire
PCDU assembly.
CAUSE
Inserting the PCDU into the machine without securing the Charge Roller Lever.
SOLUTION
Apply the Charge Roller lever on top of the broken part
Part Number : D1949100
Part Description : Charge Roller Lever
Note: This solution only works if the remaining part in the red circle is still in the PCDU
<Procedure for applying the part>
1. Pull out the affected PCDU
2. Turn the broken lever to the close position
T
echnical
Troubleshooting
Mechanical
Paper path
Product Safety
B
ulletin
Date:
7-May-18
Part information
Electrical
Transmit/receive
Other (
)
PAGE: 1/2
No.:
RD074141
Prepared by:
H Kawamura
Action required
Service manual revision
Retrofit information
Tier 2
Tier 0.5