Model:
Taurus-C1/P1 (D074/D075/M044)
Subject:
Troubleshooting residual image (uneven density)
From:
PP Service Planning Department 1G
Classification:
Symptom
a) Image density is fainter in the area 115mm in width from the leading edge when printing
a halftone image immediately after printing a solid image on the 75ppm model. On the
65ppm model, the faint density appears in the area 65mm in width from the leading
edge.
NOTE: 115mm corresponds to the paper interval distance
b) After printing a bold image, the image appears as a residual image positioning 188mm
behind the bold image.
NOTE: 188mm corresponds to the circumference of the OPC drum.
NOTE: Symptom "b" will be added in the "Troubleshooting ORU (TCRU)" document.