Model:
Taurus-C1a/C1b (D074/D075)
Subject:
Procedure for Attaching the Anti-Toner Leak Spring
Plate
From:
1st PP Tech Service Sec., PP Tech Service Dept.,
Classification:
Please add the following procedure for attaching the Anti-Toner Leak Spring Plate on the
Development unit to your field service manual. The plate is newly registered as a service
part.
D0743270: PLATE:CASE:FILTER
Procedure
CAUTION: The edge of the spring plate is sharp. Make sure to hold the flat surface of the
spring plate to avoid injuries.
1. Remove the development unit from the PCDU according to the procedure in the field
service manual in the section:
4. Replacement and Adjustments -> Photoconductor Development Unit (PCDU) ->
Development Unit Replacement
T
echnical
Troubleshooting
Mechanical
Paper path
Product Safety
B
ulletin
Date:
21-May-12
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
PAGE: 1/4
No.:
RD074069
Shinnosuke Sasaki
Action required
Service manual revision
Retrofit information
Tier 2