Ricoh Taurus-C1a Technical Bulletin page 354

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus C1/P1 (D074/D075/M044)
Subject:
SC672 Description Added to FSM
From:
st
1
PP Tech Service Sec., PP Tech Service Dept.
Classification:
Please add the following description to your Taurus field service manual in the section:
6. Troubleshooting
SC672
D
Controller-to-operation panel communication error at startup
After powering on the machine, the communication circuit between the controller and
the operation panel is not opened, or communication with controller is interrupted after
a normal startup.
Controller stall
Controller board installed incorrectly
Controller board defective
Operation panel connector loose or defective
1. Check the harness connection.
2. Check the board installation.
3. Replace the controller board.
echnical