Ricoh Taurus-C1a Technical Bulletin page 455

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1a/C1b (D074/D075)
Flow chart
Start
Print 3 sheets of full-page solid and
1-dot halftone (SP2-109-003: "26"
and "11") on A3/DLT in black, cyan,
magenta, and green.
Does the line appear
at the same locations
on the printouts?
No
Clean the toner shield glass of
the affected color.
Print the job confirmed
of the problem.
Yes
Has the problem
resolved?
No
Clean the doctor gap.
(See Note2.)
Print the job confirmed of the
problem.
Yes
Has the problem
resolved?
Finish
echnical
T
Compare Cyan and Green prints
to verify if the white line is
caused by the Y dev unit.
Yes
Verify the dev unit causing the
problem.
[Tip]
Since the PCDUs are positioned in
the order of Y, M, C, K from left to
right, if, for example, the problem is
observed in yellow and magenta,
check the M dev unit.
No
ulletin
B
Date:
20-Mar-14
Any foreign
substances stuck
at the bottom
side of the dev
unit?
No
Contact your supervisor.
No.:
RD074118
Yes
Clean the bottom
side of the dev
unit. (See Note1.)
Print the job confirmed
of the problem.
No
Has the problem
resolved?
Yes
PAGE: 3/25