Ricoh Taurus-C1a Technical Bulletin page 258

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Reissued:20-Jun-12
Model:
Taurus-C1/P1 (D074/D075/M044)
10. Remove the fusing drive unit. (Screw x3)
11. Remove the pulley. (E-type retaining ring x1)
12. Remove the 3 screws to separate the shaft assembly from the motor bracket.
IMPORTANT: As you separate the components after removing the 3 screws, hold it so
After removing the 3 screws, flip the unit so that the motor
bracket faces up to prevent the gears from dropping.
echnical
T
that the motor bracket faces up and the shaft assembly faces down to
prevent the gears from dropping.
ulletin
B
Date:
16-May-12
PAGE: 6/8
No.:
RD074068a