Reissued:30-Jan-14
Model:
Taurus-C1/P1 (D074/D075/M044)
Procedure required after cleaning the ITB speed sensors
Make sure to perform the following procedure after cleaning the ITB speed sensors.
1. Turn on the machine power and wait until it becomes ready.
2. Open both front doors.
3. Remove the front cover of the ITB cleaning unit.
4. Rotate both levers of the ITB cleaning unit clockwise to retract the blades from the ITB.
5. Execute SP2920-001 while the front door is open.
6. Close the front doors. The machine starts the initialization process.
7. Wait until "Completed" is displayed on the operation panel.
8. Rotate both levers of the ITB cleaning unit counter-clockwise and install the front cover.
9. Close the front doors.
10. Execute SP2-912-001 (Encoder Sn:Adj Light: Adj Light Amt).
11. Turn the main switch off and then on.
12. Execute SP2-914-001 (Encoder Sn:Get 1stPhase: Get Phases: Execute All).
13. Turn the main switch off and then on.
14. Check the value of SP2-915-001 (Encoder Sn Ctrl Condition: Scale FB Control Enable)
If the value is "1", the feedback control is properly turned on.
If the value is "0," repeat the sensor cleaning procedure until you confirm value "1".
15. Execute SP3011-4 (Manual ProCon: Exe: Full MUSIC) to complete the procedure.
echnical
T
B
ulletin
Date:
3-Jul-12
PAGE: 2/2
No.:
RD074077b