Model:
Taurus-C1/P1 (D074/D075/M044)
Subject:
Field Service Manual Correction (SC682)
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Service Manual Correction
6. Troubleshooting > SC Tables > SC600: Communications > SC682 RFID ID Chip
Communication Error: PCU
No.
Sub code
SC682
001 ~ 004
006 ~ 009
011 ~ 014
016 ~ 019
021 ~ 024
026 ~ 029
031 ~ 034
T
echnical
Troubleshooting
Mechanical
Paper path
Product Safety
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
ID Chip at PCU communication error: ID error
The system made three unsuccessful attempts to communicate with the
ID chip on the PCU.
D
ID chip data corrupted
Replace PCU
Cycle the machine off/on
ID Chip at PCU communication error: Channel Error
The system made three unsuccessful attempts to communicate with the
ID chip on the PCU.
D
Disconnected Interface
Replace PCU
Cycle the machine off/on
ID Chip at PCU communication error: Device Error
The system made three unsuccessful attempts to communicate with the
ID chip on the PCU.
D
ID chip missing
Replace PCU
Cycle the machine off/on
ID Chip at PCU communication error: Interfered Communication
The system made three unsuccessful attempts to communicate with the
ID chip on the PCU.
D
Electrical noise
Replace PCU
Cycle the machine off/on
ID Chip at PCU communication error: Communication Time Out
The system made three unsuccessful attempts to communicate with the
ID chip on the PCU.
D
Electrical noise
Replace PCU
Cycle the machine off/on
ID Chip at PCU communication error: Device not operating
Electrical noise
D
Replace PCU
Cycle the machine off/on
D
ID Chip at PCU communication error: Buffer Full
B
ulletin
Date:
10-Aug-2012
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
PAGE: 1/2
No.:
RD074087
S. Sasaki
Action required
Service manual revision
Retrofit information
Tier2