< Decurler Unit (D544) \ Accessories >
Change in quantity of the Screw
Before the Revision
4.
Screw (M4×8)
< Decurler Unit (D544) \ Installation >
Description of handling the Decurler unit was changed accordingly with the addition of
mylar.
Before the Revision
1. Prepare a place to lay the Decurler Unit.
• Lay the Decurler Unit on a soft surface, like a
piece of cardboard or a folded drop cloth. Do
not lay the Decurler Unit on the floor.
T
B
echnical
• Set SP5965-1 to "1" if you want to have the
10
4.
1. Prepare a place to lay the Decurler Unit [A].
2. Lay the Decurler Unit [A] on the carton box [B] as
• Keep this position before attaching this unit to the
ulletin
Date:
21-Oct-11
heaters on at all times. Use this setting only if
the work area is extremely humid or
exceptionally cold.
After the Revision
Screw (M4×8)
After the Revision
shown above so that the entrance gate of the
decurler unit does not touch any object or the
floor.
main machine.
• Do not lay the Decurler Unit on the floor with
the entrance gate of the decurler unit facing
downward. Otherwise, the mylars [C] on the
entrance gate may be bent or folded.