Ricoh Taurus-C1a Technical Bulletin page 565

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1/P1 (D074/D075/M044)
Subject:
FSM Correction: SC570
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Please add the following description in bold on SC570 to your field service manual in
section:
6. Troubleshooting  SC Tables  SC570
SC570
D
Ozone Collection Fan Error
The ozone collection fan is the large fan on the right end the upper
horizontal dust across the back of the machine.
Fan harness disconnected or broken
Fan overload due to physical obstruction
Fan motor defective
Replace the following fans.
Ozone collection fan
Ozone exhaust fan (Y)
Ozone exhaust fan (M)
Ozone exhaust fan (C)
Ozone exhaust fan (K)
Cooling Box Ozone Exhaust Fan (This is at the rear box)
Ozone filter
If the fan did not solve, replace the harness connected to above
fans.