Ricoh Taurus-C1a Technical Bulletin page 62

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1 / P1
<Main Machine \ Checking the Print Quality \ Image Shift Check between the 1st and
2nd Pages >
The following procedure was changed.
Before the Revision
Procedure
1. Turn on the main power switch.
2. Press the "User Tool" button, and then the
"Adjustment Settings for Skilled Operators"
button.
3. Select "0703: Switch Print Screen".
4. Select "Printer", then touch [OK] (Default: Copy).
5. Select "0101:Adjust Image Position With Feed
Direction".
6. Press the "To Print Screen" button on the top of
the LCD.
7. Select Tray and duplex print mode.
8. Press the [Print] button, and then [OK] to print the
"Adjustment Printing" test pattern.
<Main Machine \ Checking the Print Quality \ Image Skew Check >
Print quality check procedure (skew) for M044 was added.
Before the Revision
Procedure: Measurement
1. Turn on the main power switch.
2. Enter the SP mode (System SP).
3. Open SP5070-1 (Switching Print Application), and
then select "6" (Printer).
4. Touch the "COPY Window" button at the top of the
display.
5. Select a tray and the duplex print mode.
6. Touch [Print] to print the "Adjustment Printing" test
pattern.
7. Measure the distance in the main scan direction
between the image edge and paper edge at
points [A1] and [A2] shown above.
Acceptable range: [A1] - [A2] < ±0.5 mm (A4 or LT
SEF or more)
T
B
echnical
Procedure
1. Turn on the main power switch.
2. Press the "User Tool" button, and then the
"Adjustment Settings for Skilled Operators" button.
3. For the D074/D075 only:
4. Select "0101:Adjust Image Position With Feed
5. Press the "To Print Screen" button on the top of
6. Select Tray and duplex print mode.
7. Press the [Print] button, and then [OK] to print the
"Adjustment Printing" test pattern.
Procedure: Measurement Using the "Adjustment
Printing" Test Pattern
1. Turn on the main power switch.
2. M074/M075: Open SP5070-1 (Switching Print
3. Touch the "COPY Window" (D074/D075) or "APL
4. Select a tray and the duplex print mode.
5. Touch [Print] to print the "Adjustment Printing" test
6. Measure the distance in the main scan direction
between the image edge and paper edge at points
[A1] and [A2] shown above.
Acceptable range: [A1] - [A2] < ±0.5 mm (A4 or LT
SEF or more)
Procedure: Measurement Using "Trimming Area"
ulletin
Date:
21-Oct-11
After the Revision
• Select "0703: Switch Print Screen"
• Select "Printer", then touch [OK] (Default:
Copy).
Direction".
the LCD.
After the Revision
Application), and then select "6" (Printer)
(D074/D075).
Window" (M044) button at the top of the display.
pattern.
PAGE: 14/58
No.:
RD074026

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taurus-c1b

Table of Contents