Ricoh Taurus-C1a Technical Bulletin page 29

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1 (D074/D075)
Correction 5: Revised "After Replacement" Procedure for ITB Lubrication Blade
Please ignore the "After Replacement" Procedure for ITB Lubrication Blade as described
in the FSM and use the following procedure instead:
Replacement and Adjustments > Image Transfer Belt (ITB) Unit > Lubrication Blade
1. Install the cleaning unit. (Keep the levers in the "unlocked" position. Do not attach the
cover yet.)
2. The machine power must be OFF.
3. Remove the PTR unit.
4. Turn the main power switch ON and close both front doors.
5. Enter the SP mode.
6. Reset the counter for the replaced unit or parts.
7. Open the right front door, and access SP2310-1 (Force Lubricant – Belt Cleaning).
8. Immediately after the above step, close the right front door to run the above SP.
9. Wait for about 5 minutes. When you see "Completed" displayed on the operation panel,
you are ready to continue.
10. Reinstall the PTR unit.
11. Rotate both levers of the ITB cleaning unit counter-clockwise and install the front cover.
12. Execute these SP codes.
SP
3020-001
3012-001
13. Exit the SP mode.
T
echnical
Initializes process control
Confirm successful initialization of process control
B
ulletin
Date:
22-Jun-2011
What It Does
PAGE: 9/14
No.:
RD074015a

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taurus-c1b

Table of Contents