Correction 6: Revised "After Transfer Belt Replacement" Procedure
Please ignore the "After Transfer Belt Replacement" Procedure for ITB Lubrication Blade
as described in the FSM and use the following procedure instead:
Replacement and Adjustments > Image Transfer Belt (ITB) Unit > After Transfer Belt Replacement
1. The machine power must be OFF.
2. Open both front doors.
3. Remove the front cover of the ITB cleaning unit.
4. Rotate both levers of the ITB cleaning unit clockwise to retract the blades from the ITB.
5. Remove the PTR unit.
6. Turn the main power switch ON and close both front doors.
7. Enter the SP mode.
8. Reset the counter for the ITB belt.
9. Open the right front door, and execute SP2310-1 (Force Lubricant – Belt Cleaning).
10. Immediately after the above step, close the right front door to run the above SP.
11. Wait for about 5 minutes. When you see "Completed" displayed on the operation panel,
you are ready to continue.
12. Reinstall the PTR unit.
13. Rotate both levers of the ITB cleaning unit counter-clockwise and install the front cover.
14. Do SP2912-1. This SP adjusts the strength of the LED beam of the ITB feed-back
sensors (main sensor and sub sensor).
15. Do SP2914-1. This SP code resets the ITB feed-back sensors.