Ricoh Taurus-C1a Technical Bulletin page 135

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1a/C1b (D074/D075)
Subject:
Service Manual Revision: SC995
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Please add the following description to your Taurus field service manual in the section:
6. Troubleshooting > SC Tables > SC900: Other.
Added Description
SC995 table
SC995
SC995-01
SC995-02
SC995-03
SC995-04
Note
One example of a case where the above SC occurs is when a control board for the 65cpm
machine is mistakenly installed in a 75cpm machine or vice versa. (SC995-03 could be
initiated in this case.)
T
echnical
Troubleshooting
Mechanical
Paper path
Product Safety
B
ulletin
Date:
12-Jan-12
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
Serial Number Setting Incorrect
The 11-digit serial number is printed on the data
plate. This information is compared
with the installed components to detect
mismatches.
D
Serial Number Mismatch 1
Enter the correct information for the
model with SP5811 or use the
previous NVRAM.
Cycle the machine off/on.
D
NVRAM Mismatch
Use the previous NVRAM.
-or-
If the NVRAM must be replaced:
Prepare an SD card with the current
model information.
Do SP5825 to download the new
model information from the SD card
to new NVRAM.
Remove the SD card.
Cycle the main machine off/on.
D
Controller Mismatch, or Controller Board
Defective
You must install the CTL controller board
designed for use with this machine.
D
Serial Number Mismatch 2
Reinstall the components which have
been removed from the machine.
PAGE: 1/1
No.:
RD074039
Shinnosuke Sasaki
Action required
Service manual revision
Retrofit information