Reissued:18-Feb-13
Model:
Taurus-C1/P1 (D074/D075/M044)
49: Txt Ppr: Ppr Trns Isolatn Voltag: Side 2
Adjust the separation voltage for paper transfer applied to side 2 when the profile of a textured paper (paper
displayed as [Txt Textured***-*** gsm ***] in the paper library) is registered as a custom paper.
Press [+] or [-] to adjust the voltage.
Setting Item
Txt Ppr: Ppr Trns Isolatn Voltag: Side 2
To cater for the additional adjustment functions, change the numbering of the items in "Custom Paper
Settings for Administrators" as follows:
Fusing Heat Roller Temperature Adj
Fusing Pressure Roller Temperature Adj
Fusing Nip Width Setting
Paper Feed Interval Setting
Reduce Initial CPM: Low Temp. Envrnmt
Reduce Initl CPM: Norml/High Temp Env
Adjust Cleaning Web Motor Interval
Decurler Feed Speed Adj: Curl Adj Off
Decurler Feed Speed Adj: Curl Adj Weak
Decurler Feed Speed Adj: Curl Adj Strg
Adjust Z-fold Position 1
Adjust Z-fold Position 2
Half Fold Position: Single-sheet Fold
Letter Fold-out Posn 1: Single-sheet Fld
Letter Fold-out Posn 2: Single-sheet Fld
Letter Fold-in Posn 1: Single-sheet Fold
Letter Fold-in Posn 2: Single-sheet Fold
Double Parallel Fold Position 1
Double Parallel Fold Position 2
Adjust Gate Fold Position 1
Adjust Gate Fold Position 2
Adjust Gate Fold Position 3
echnical
T
Item
ulletin
B
Date:
08-Jan-13
Max. Value
Min. Value
12
0
Old numbering
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
PAGE: 17/20
No.: RD074097c
Step
Unit
0.1
kV
New numbering
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71