Ricoh Taurus-C1a Technical Bulletin page 309

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Reissued: 30-Nov-15
Model:
Taurus-C1/P1 (D074/D075/M044)
RTB Reissue
The item in bold italics were corrected or added.
Subject:
Troubleshooting SC26x
From:
1st PP Technical Service Section
Classification:
Symptom
SC265 Skew Control: Out of Range Error (C)
SC266 Skew Control: Out of Range Error (M)
SC267 Skew Control: Out of Range Error (Y)
Note
SC26x is logged internally and does not appear on the operation panel. The symptom
can be noticed by SC285 as a result of SC26x that occur in series.
Cause
Defective skew motor
Action
Replace the skew motor p/n D0741920 (DC STEPPER MOTOR:ASS'Y) by following the
procedure described below.