Reissued:19-Sep-13
Model:
Taurus-C1a/C1b (D074/D075)
Note
 There are two types of drum charge units; one with the washers [B] and one without
the washers.
 If you find any grease adhered to the drum charge roller, wipe it off with a clean wet
cloth and wait until the surface dries naturally. DO NOT use ethanol or organic
solvent to clean the charge roller. Doing so will cause damage to the charge roller.
4. Put back the drum charge roller into its case in two steps. First, place the drum
charge roller on the case so that the projections [A] on both ends are inside the slits.
Then, press down both ends and confirm correct installation by the click sound.
Note
Work carefully and keep in mind the electrodes [A] to avoid injuries when pressing down
the drum charge roller.
5. Reinstall the drum charge unit according to the service manual to complete the
procedure.
T
B
echnical
[A]
ulletin
Date:
25-Jan-12
[A]
PAGE: 3/3
No.:
RD074041a