Please apply the following corrections to your Taurus field service manual in the section:
6. Troubleshooting > SC Tables > SC500: Paper Feed, Transport, Duplexing
Correction
Correct:
SC599
Cooling Box Sensor Error
The cooling box sensor detects unusual values.
Incorrect: The following description in the current FSM is incorrect
Note
The possible actions for this SC are as follows:
Fix the leak and refill the liquid.
Reconnect the connectors.
Replace the sensor.
Replace the IOB board.
Replace the harness.
T
echnical
The cooling liquid dropped below the threshold
Connector disconnected or defective
IOB defective
Harness shorted
B
ulletin
Date:
13-Feb-12
Prepared by:
Part information
Electrical
Transmit/receive
Other (Manual
Correction)