Reissued:1-Oct-13
Model:
Taurus-C1a/C1b (D074/D075)
Doctor Gap Cleaning Procedure
1. Remove the casing. (Screw x3)
2. Tilt the unit 90 degrees so that the left side (viewed from the front) faces the bottom,
then rotate the dev roller in the direction indicated with the arrow (counterclockwise
viewed from rear) until the loose developer on the roller surface is cleaned off.
IMPORTANT
DO NOT rotate the dev roller in the opposite direction, as this will cause the Mylar to get
sucked into the roller.
3. Insert the cleaning tool into the doctor gap from the corner without the angled tab. The
tab scrapes off the toner/dust adhered to the doctor blade as you slide the tool across
the doctor gap.
T
B
echnical
ulletin
Date:
27-May-13
PAGE: 2/4
No.:
RD074104a