Ricoh Taurus-C1a Technical Bulletin page 477

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1a/C1b (D074/D075)
Procedure required after cleaning the ITB speed sensors
Make sure to perform the following procedure after cleaning the ITB speed sensors.
1.
Execute SP2-912-001 (Encoder Sn:Adj Light: Adj Light Amt).
2.
Turn the main switch off and then on.
3.
Execute SP2-914-001 (Encoder Sn:Get 1stPhase: Get Phases: Execute All).
4.
Turn the main switch off and then on.
5.
Check the value of SP2-915-001 (Encoder Sn Ctrl Condition: Scale FB Control Enable)
 If the value is "1", the feedback control is properly turned on.
 If the value is "0," repeat the sensor cleaning procedure until the value is "1".
6.
Execute SP3011-4 (Manual ProCon: Exe: Full MUSIC) to complete the procedure.
echnical
T
B
ulletin
Date:
20-Mar-14
PAGE: 25/25
No.:
RD074118

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taurus-c1b

Table of Contents