Grounding The Cabinet; Removing The Right Side Panel; Attaching The Ground Wires - NEC DS2000 Hardware Manual

Hide thumbs Also See for DS2000:
Table of Contents

Advertisement

Grounding the Cabinet

Grounding the Cabinet

Removing the Right Side Panel

Remove the cabinet right side panel to gain easy access to the ground lugs and system cabling. The cabinet
has two ground connections: ETH (Earth Ground) and PBXG (PBX Ground).
To remove the right side panel (Figure 1-8):
1.
Remove the two screws that secure the right side panel to the cabinet.
2.
Carefully slide the right side panel down until it swings clear of the cabinet.

Attaching the Ground Wires

The system provides two ground terminations. Each ground connects from the system to the ground termina-
tion using 12 AWG stranded copper wire.
G
Use the ETH (Earth Ground) for safety/system ground. You must connect ETH to a known earth ground.
G
Use the PBXG (PBX Ground) if you have trunks that require telco ground (such as ground start trunks).
This ground is not required for loop start trunks.
1-12 N Section 1: Installing the Cabinet
Figure 1-8: Removing the Right Side Panel
You must connect your system to a known earth
ground according to the following instructions.
4 Slot Cabinet Shown
!! Important !!
DS2000 Hardware Manual

Advertisement

Table of Contents
loading

Table of Contents