Check the wire between J8820 and J8847 for an open circuit or a short circuit (BSD 12.5
Flag 5). The wire between J8820 and J8847 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Measure the resistance of the Staple Move Motor between J8820-2 (COM) and each
point of J8820-1/3, and between J8820-5 (COM) and J8820-4/6 (BSD 12.5 Flag 5). The
resistance is approx. 10Ohm.
Y
N
Replace the Staple Move Motor (PL 17.8).
Measure the voltage between the Finisher PWB P8847-3 (+) and GND (-), and between
P8847-4 (+) and GND (-) (BSD 12.5Flag 5). The voltage is approx. +24VDC.
Y
N
Replace the Finisher PWB (PL 17.12).
Replace the Staple Move Motor (PL 17.8). If the problem persists, replace the Finisher
PWB (PL 17.12).
Replace the Finisher PWB (PL 17.12).
Status-indicator-raps
012-296, 012-301
012-301 Finisher Top Cover Open RAP
BSD-ON:12.1
The Finisher Top Cover is open.
Initial Actions
Power Off/On
Opening/closing of the Finisher Top Cover.
Procedure
Check opening/closing of the Finisher Top Cover. The Finisher Top Cover can be opened/
closed.
Y
N
Reinstall the Finisher Top Cover correctly.
Check the installation of the Top Cover Interlock Switch. The Top Cover Interlock Switch is
installed correctly.
Y
N
Install the Top Cover Interlock Switch correctly.
Execute Component Control [012-301 Top Cover Interlock Switch]. Open/close the Finisher
Top Cover. The display changes.
Y
N
Check the connections of P/J8808 and P/J8851. P/J8808 and
nected correctly.
Y
N
Connect P/J8808 and P/J8851.
Check the wire between J8808 and J8851 for an open circuit or a short circuit (BSD 12.1
Flag 3/Flag 4). The wire between J8808 and J8851 is conducting without an open
circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Check the conductivity of the Top Cover Interlock Switch between J8808-3 and J8808-4
(BSD 12.1 Flag 3/Flag 4). The wire between J8808-3 and J8808-4 is connecting suc-
cessfully when the Top Cover Interlock Switch contact is closed, and is insulated
when the contact is opened.
Y
N
Replace the Top Cover Interlock Switch (PL 17.12).
Replace the Finisher PWB (PL 17.12).
Replace the Finisher PWB (PL 17.12). If the problem persists, replace the MCU PWB (PL
11.1).