012-223 (A-Finisher) Front Tamper Home Sensor OFF Fail
BSD-ON:CH15.4
At the end of the operation to turn Off the Front Tamper Home Sensor that was On, the
Front Tamper Home Sensor was not detected being Off.
The Front Tamper Home Sensor should have turned Off and then the Front Tamper Motor
stopped, but the Front Tamper Home Sensor was On.
Initial Actions
Check the Front Tamper Home Sensor is properly installed and has no foreign object and
that the actuator is not broken.
Power Off/ON.
Procedure
Check the Front Tamper for any foreign object, deformation and binding that prevents it from
moving. The Front Tamper free from defects and binding.
Y
N
Repair the deformation and remove the foreign object(s) and the binding.
Check the drive mechanism to the Front Tamper for a deformed or broken part and not-seated
gears. The drive mechanism is free from defects and the gears seat properly.
Y
N
Repair the Front Tamper drive mechanism.
Run DC330[012-220].
Enter Component Control [012-220]. Move the Front Tamper by hand to block and unblock the
Front Tamper Home Sensor. The display changes.
Y
N
Check the connections of P/J8700 and P/J8724. P/J8700 and P/J8724 are securely
connected.
Y
N
Connect P/J8700 and P/J8724 securely.
Check for an open or short circuit between J8700 and J8724. The
J8700 and J8724 are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB J8700-6 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to Wirenet 7.2.36 A-Finisher +5VDC and check the +5VDC circuit.
Measure the voltage between Finisher PWB J8700-5 (+) and GND (-). Move the Front
Tamper by hand to block and unblock the Front Tamper Home Sensor. The
changes.
Y
N
Replace the Front Tamper Home Sensor (PL 22.10).
A
B
Status-indicator-raps
012-223 (A-Finisher)
A
B
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (PL 22.7).
Enter [012-020] and [012-023] alternately. The Front Tamper Motor rotates.
Y
N
Check the connections of P/J8710, P/J8738A and P/J8738B. P/J8710, P/J8738A and
P/J8738B are securely connected.
Y
N
Connect P/J8710, P/J8738A and P/J8738B securely.
Check for an open wire or short circuit between J8710, P/J8738A and J8738B. The wire
between J8710, P/J8738A and J8738B are OK.
Y
N
Repair the open wire or short circuit.
Measure the voltage between Finisher PWB J8710-5 (+) and GND (-), and between
J8710-7 (+) and GND (-). Each voltage is approx. +24VDC.
Y
N
Go to Wirenet 7.2.38 A-Finisher +24VDC and check the +24VDC circuit. If the prob-
lem continues, replace the Finisher PWB (PL 22.7).
Replace the Front Tamper Motor (PL 22.10). If the problem continues, replace the Fin-
isher PWB (PL 22.7).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (PL 22.7).
wires
between
voltage
January 2007
2-174
Revision
WorkCentre 7132

Hide quick links:

Advertisement

Table of Contents
loading