A
B
Check the wire between J787 and J786 for an open circuit or a short circuit (BSD 5.2 Flag
5). The wire between J787 and J786 is conducting without an open circuit or a short
circuit.
Y
N
Repair the open circuit or short circuit.
Measure the voltage between the DADF PWB P786-1 (+) and GND (-) (BSD 5.2 Flag 5).
The voltage is approx. +24VDC.
Y
N
Replace the DADF PWB (PL 16.3).
Replace the DADF Nudger Motor (PL 16.6) If the problem persists, replace the DADF
PWB (PL 16.3).
Replace the DADF PWB (PL 16.3).