23.5.7

CWP - Configure Webserver Ports

This command allows you to configure the Webserver ports.
• HTTP Port [Default = 80] (range 1-65536)
• HTTPS Port [Default = 443] (range 1-65536)
23.5.8
CWT - Configure Webserver Timeouts
• HTTPS Timeout [Default = 20000 MilliSec](range 5000-50000 MillisSec)
• HTTP Timeout [Default = 10000 MilliSec](range 5000-50000 MillisSec)
23.5.9
DBG - Debug [0|1|2|3]
To log key messages received to the java console, do the following
• DBG 0: this tells the box to not send messages to the GUI
• DBG 1: this tells the box to send basic messages to the GUI
• DBG 2: this tells the box to send more specific messages to the GUI
• DBG 3: this tells the box to send even more specific messages to the GUI
Open the Java console to see the messages. A line surrounded by square brackets is written
to the Java console whenever a button is pressed, an X10 message is received, or a status
change occurs. This is useful for determining whether or not the PLM has seen a button
press or X10 message and sent it to the ISY.
23.5.10 EI|DI – Enable/Disable Internet Access
To enable access to this device from the internet, type EI at the shell prompt. By default
internet access is disabled.
To disable access to this device from the internet, type DI at the shell prompt.
23.5.11 ET|DT – Enable/Disable Telnet Access
To enable telnet access, type ET at the shell prompt. By default, Telnet Access is enabled.
To disable telnet access, type DT at the shell prompt.
Note: If there's already a telnet session open, the session will continue to function until the
user exits the shell.