10.4 Device Intensity Level Arguments

With a device you have several options on what can be performed with them. Depending on
if the device is a relay or a dimmer the ISY will provide the proper arguments for it. Here is
a list of what each argument equates to.
• On/Off
o On - sends the INSTEON "Single Tap ON" command
▪ On means 100% for dimmer devices, select a Level (1-99%) if this is
▪ On will set a Scene to it's selected levels using the ramp rates set in
o Off - sends the INSTEON "Single Tap OFF" command
o Fast On - sends the INSTEON "Double Tap ON" command
o Fast Off - sends the INSTEON "Double Tap OFF" command
• Level
o Brighten - sends the INSTEON "Hold Press BRIGHTEN" command
o Dim - sends the INSTEON "Hold Press DIM" command
o Fade Up - sends a INSTEON "Manual Change Level UP" command, that says
active until an ISY "Fade Stop" command
o Fade Down - sends a INSTEON "Manual Change Level DOWN" command, that
says active until an ISY "Fade Stop" command
o Fade Stop - sends a INSTEON "Manual Change Level STOP" command, which
ends an active ISY "Fade Up" or ISY "Fade Down" command
• Status
o Query - triggers the ISY to check an "ISY node" for status
not the desired result.
the scene.