$Alarm.level = 3. Same as level 2 but with remote notifications that beepers are going in the
house.

11.10.2.5Program: Alarm level 3

If
$sAlarm.level is 3
Then
Set 'Mudroom / MudRm Beeper' On
Set 'Utility Room / Util Beeper' On
Send Notification to 'Text Larry' content 'House Beeping'
Wait 1 second
Send Notification to 'eMail Larry' content 'House Beeping'
Wait 30 seconds
Set 'Mudroom / MudRm Beeper' Off
Set 'Utility Room / Util Beeper' Off
$sAlarm.level = 0
Else
- No Actions - (To add one, press 'Action')
Level 3, In-house, and remote notifications,
$Alarm.level = 4. Medium duration, beepers, flashes all inside and outside lights, noise
makers, and send notifications that house lights are flashing