14.1.4

Program Status Kitchen Counter (K5)

If
X10 'K5/On (3)' is Received
And X10 'K5/Off (11)' is not Received
And X10 'K/All Units Off (13)' is not Received
Then
Set Program 'Resume Kitchen Counter (K5)' To Run At Startup
Else
Set Program 'Resume Kitchen Counter (K5)' To Not Run At Startup
14.1.5
Program Resume Kitchen Counter (K5)
If
- No Conditions - (To add one, press 'Schedule' or 'Condition')
Then
Run Program 'Status Kitchen Counter (K5)' (Then Path)
Else
- No Actions - (To add one, press 'Action')
When the Status program is True, the Resume program is set to run at startup, and will set
the Status program back to True. When the Status program is False, the Resume program
does not run at startup, and the Status program therefore remains in its initial startup state
of False (see the section 9.5
Most X-10 dimmer devices, on the other hand, do not necessarily return to the former state
after a power failure, and may in fact power up to an unknown state. Such devices may be
reset to the pre-power-fail on/off state by the use of three programs per device:
Scope, Precedence and Execution
Order).