11.10.2.6Program: Alarm level 4

If
$sAlarm.level is 4
Then
Set 'Mudroom / MudRm Beeper' On
Set 'Utility Room / Util Beeper' On
Send Notification to 'Text Larry' content 'House Alarming '
Send Notification to 'Text Jackie' content 'House Alarming '
Wait 1 second
Send Notification to 'eMail Larry' content 'House Alarming '
Send Notification to 'eMail Jackie' content 'House Alarming '
Repeat 5 times
Set 'Alarm scene flasher' Fast On
Wait 2 seconds
Set 'Alarm scene flasher' Fast Off
Wait 2 seconds
Repeat 1 times
Set 'Mudroom / MudRm Beeper' Off
Set 'Utility Room / Util Beeper' Off
Wait 1 second
$sAlarm.level = 0
Else
- No Actions - (To add one, press 'Action')