Troubleshooting - Universal Devices ISY-994i User Manual

Home automation
Hide thumbs Also See for ISY-994i:
Table of Contents

Advertisement

From Elk RP2
▪ Go to Automation, right+click on Lighting, and select Import Lighting Data ...
▪ Enter the name of the export file.
▪ Select Universal Devices ISY export for an Insteon network
▪ Click the [Import] button
▪ Click [Send to Control] button (you may need to connect first)
▪ Click the Save icon below the main menu bar

6.11.3.6Troubleshooting

Symptom
▪ If the Elk is configured, the ISY-99i Admin Console is slow and unresponsive
▪ The ElkRP software does not connect/transfer data reliably
▪ The data about the ELK is not loaded into the ISY-99i (you don't see the zone and
area topology)
Solution
▪ You most likely have the ELK Module in the ISY-99i configured with the secure port
on the ELK M1XEP (e.g. 2601), and the result is that the ISY-99i apparently floods
the network trying repeatedly to connect to the secure socket, even though it
requires a non-secure socket.
Symptom
▪ Not receiving updates from Elk although ISY is connect to Elk
Solution
▪ You most likely do not have the Serial Checkboxes in Elk Globals G29-42 selected
(see Configuring Elk above for details)
Symptom
▪ Arm/Disarm does not work from the Admin Console
Solution
▪ The RP Access Code is strictly the code that will allow a connection to be made
between ELK-RP and the ELK-M1. It can't be used to arm/disarm the M1. And please
note that a User Code and the RP Access Code should not be programmed with a
matching code
▪ Please confirm that your ELK system doesn't have the "Access" attribute (box)
checked for the User Code that is associated with the ISY system. The "Access"
Page | 97

Advertisement

Table of Contents
loading