11.4.1.1Program: Var_RainInPast36Hours

This is an empty flag program. It is set and managed by two programs
Weather_RainCountdown and Weather_RainFall.
If
- No Conditions - (To add one, press 'Schedule' or 'Condition')
Then
- No Actions - (To add one, press 'Action')
Else
- No Actions - (To add one, press 'Action')
11.4.1.2Program: Weather_RainCountdown
When triggered, it sets the Var_RainInPast36Hours program to true, waits for 36 hours,
then sets the same to false. The countdown program is broken out into another program
because the first program was stopping during the Wait portion whenever WeatherBug
reported Rain Today as zero inches (because the conditions were being re-evaluated). This
way the countdown should run uninterrupted for 36 hours.
If
- No Conditions - (To add one, press 'Schedule' or 'Condition')
Then
Run Program 'Var_RainInPast36Hours' (Then Path)
Wait 36 hours
Run Program 'Var_RainInPast36Hours' (Else Path)
Else
- No Actions - (To add one, press 'Action')