9.8.2.11Program: Fan Off

If
Control 'Utility Room Fan' is switched Off
Or Control 'Utility Room Fan' is switched Fast Off
Then
Stop program 'Run 15 min'
Stop program 'Run 30 min'
Stop program 'Run 60 min'
Stop program 'Run 90 min'
Run Program 'Flag 1' (Else Path)
Run Program 'Flag 2' (Else Path)
Set 'Utility Room Fan' Off
Else
- No Actions - (To add one, press 'Action')

9.8.3 Programs as Variables: ISY Restores KPL State After Power Loss

This set of programs demonstrates how to 'memorize' the state of a keypad button and
restore it after a power loss.
Keypad buttons can only be controlled when they are a member of a scene.
Scene: sbGreen
KPLg as responder
This program will run whenever the keypad button changes state:
29
(posted by Darrell Peters)
29