11.5.4.3Program: Arm Keypad Combo

If
$sKeypress_sequence is $cARM.COMBO <----- predefined numeric sequence
Then
Run Program 'Armed Mode Toggle' (If) <----Replace with your program
Wait 1 second
$sKeypress_sequence = 0
Else
Wait 4 seconds
$sKeypress_sequence = 0 <----- 4 second pause causes a reset/start over
11.6 Leak Sensor Programs
11.6.1
Program for Multiple Sensors
I have 6 leak sensors that I have spent the past few months integrating in with the ISY. It
took a while to get them to perform as I wanted, and I figured this might be helpful to
others trying to figure out the same thing. Here goes...
11.6.1.1Functionality
A notification is sent twice a day for any problem with a leak sensor (i.e. missed heartbeat)
at 9:00am and 6:00pm. This avoids the inevitable single email that I ignore and the
problem goes uncorrected for weeks...
A notification is sent immediately when a leak sensor is activated (and also again twice
daily as above). This email is not sent repeatedly even if the sensor is "fluttering" at first
activation, which it commonly does.
The email notification shows the status of EVERY leak sensor (heartbeat received as
expected, heartbeat missed, sensor activation, etc.)
If the program monitoring heartbeat signals somehow fails or is shut down, a problem
notification is sent.
All functionality should survive an ISY reboot without user intervention.