Program #6 - Main Bath Motion Timer – Enabled - Universal Devices ISY-994i User Manual

Home automation
Hide thumbs Also See for ISY-994i:
Table of Contents

Advertisement

11.8.1.6Program #6 - Main Bath Motion Timer – Enabled
If
Status 'Main Bath Motion.1-Sensor' is Off
And Program 'Main Bath Motion Timer Enable' is True
Then
Wait 4 minutes
Set 'Main Bath Lights' Off
Else
- No Actions - (To add one, press 'Action')
11.8.1.7Program #7 - Main Bath Motion Timer Enable – NOT Enabled
If
- No Conditions - (To add one, press 'Schedule' or 'Condition')
Then
Set Program 'Main Bath Motion Timer Enable' To Run At Startup
Else
Set Program 'Main Bath Motion Timer Enable' To Not Run At Startup
Here we use a program (Main Bath Motion Timer Enable) as a flag to determine whether
the motion sensor should turn the light on (program 5) and whether the timer should be
allowed to turn the light off (program 6). To allow the motion sensor to turn the light on,
but prevent the timer from turning the light off, add the And Program 'Main Bath Motion
Timer Enable' is True line only to program 6 and not to program 5.
Notice first that the flag program is not enabled (the Enabled box at the right side of the
window is not checked). This means that the program will never run automatically in
response to changing conditions in the If; it will run only when told to do so either by
another program, or by manually running it from the Program Summary tab. [There is one
other condition under which it will run, and that condition will be explained in the next
paragraph.] In this case, since the program has no conditions, it will not run automatically
in any case. But clearing the Enabled box for programs which shouldn't run automatically is
a good habit to get in to.