Program: Office Light Status - Universal Devices ISY-994i User Manual

Home automation
Hide thumbs Also See for ISY-994i:
Table of Contents

Advertisement

Unfortunately, I often need to put in late nights. To account for times I might be in the office
outside of normal work hours, I also added this program to check the status of lights. If any
of the lights in my office are on, this program is true:

11.9.1.2Program: Office Light Status

If
Status 'OfficeLight1' is not Off
Or Status 'OfficeLight2' is not Off
Or Status 'OfficeLight3' is not Off
Then
- No Actions - (To add one, press 'Action')
Else
- No Actions - (To add one, press 'Action')
Finally, I wrote a notification program to let me know if there are any extreme temperature
situations that might indicate a heating/AC equipment failure. This will both email me and
send a text message to my phone if either of the conditions is true.
11.9.1.3Program: Office Safety Check
If
Status 'OfficeThermostat' > 90° (Temperature)
Or Status 'OfficeThermostat' < 60° (Temperature)
Then
Send Notification to All
Else
- No Actions - (To add one, press 'Action')
I'm up here in New England, so my thermostat controls both a furnace (for the cooler
moths) and a whole house AC (for the warmer months). My ideal goal is to simply leave the
thermostat in COOL mode in the summer, and manually switch it to HEAT mode when I
want to start using the heater, then manually back to COOL mode when I want to start
Page | 316