Program: Mbfancheck - Universal Devices ISY-994i User Manual

Home automation
Hide thumbs Also See for ISY-994i:
Table of Contents

Advertisement

This program is the central location to change the length of the fan run time - in this case it
is set to 10 minutes

11.2.1.2Program: MBFanCheck

Main Bathroom Fan Check - Please take note of the comment that the program must be
disabled
If
Status 'BedAndbath / ~Devices / Main Bathroom Light SW' < 20%
Then
Run Program 'MBFanSwOFF' (Then Path)
Else
Run Program 'MBFanSwON' (Then Path)
Note that this program must be set to DISABLED. if it isn't it will shut down the fan
immediately when the light is turned off.
When called by the timer program, the status of the light is checked.
if the light is OFF the shut down program is called.
If the light is ON the timer program is called again.
Page | 254