To run a Query on the Thermostat every 15 minutes:
If
From 12:00:00AM
For
Then
Repeat Every 15 minutes
Else
- No Actions - (To add one, press 'Action')
13.20.2.6Thermostat FAQs
If you are having trouble linking a Thermostat please check the following:
• Signal related ... too far away from the closest Access Point
• Defective dongle
• Wrong address
The version 1 Insteon thermostat does not automatically inform the ISY of its current
status. For the ISY to have a reasonable idea of the thermostat's current temp, setpoint,
mode, etc. it will need to be polled periodically.
13.21
TriggerLinc
TriggerLincs are RF devices, thus require the installation of an INSTEON RF receiver (such
as an INSTEON AccessPoint).
The TriggerLinc cannot be linked using Auto Discover. To link a TriggerLinc to the ISY,
please choose the LINK MANAGEMENT pulldown, then NEW INSTEON DEVICE. Enter the
device address manually (found inside the battery compartment), then select the "2421
TriggerLinc" from the Device Type list.
24 hours
Set 'OfficeThermostat' Query
Page | 389