To force the door lock and repeater to see each other as neighbors, please:
• Re-include the door lock after the repeater has been included into the network to
force the door lock to see the repeater as a potential neighbor. (This method may
require you to move the ISY closer since the repeater does not support NWI).
• Open Tools | Diagnostics | Event Viewer and change the Level to 3
• Wake up the door lock, and run Z-Wave | Tools | Heal Network
o Watch the Event Viewer and make sure that Heal completes without failure
for each of your Z-Wave devices
o Repeat as necessary

15.4 Configuring Aeon Labs DSB09104-ZWUS Energy Monitor

Just as any Z-Wave device, DSB09104-ZWUS has some parameters that can be configured.
The most important of which are voltage, units, and reporting interval.
• Right-mouse click on the associated node | Z-Wave | Set Configuration Parameter:
o Choose Parameter 1 from the Parameter Number drop down, for Parameter
Value enter your voltage (i.e. 120), then click the Set button
o Choose Parameter 101 from the Parameter Number drop down, for
Parameter Value enter 14 for auto reporting, then click the Set button
o Choose Parameter 111 from the Parameter Number drop down, for
Parameter Value enter the report interval (i.e. 10), then click the Set button
15.5 Configuring AeoTec Dry Contact Closure Gen 5
This specific device reports sensor events as basic report by default. In 4.5.x firmware
versions, ISY is expecting a binary sensor report and, as such, the node associated with
binary sensor is not updated. To change the behavior of this device to report events as
binary sensor report, change the configuration parameter as follows:
Parameter 121 [4 byte] = 16
15.6 Aeon Labs MultiSensor 6 Configuration Parameters
https://www.universal-devices.com/docs/Aeotech-MS6-Config-Params.pdf
15.7 Aeon Labs DSB28-ZWUS Configuration Parameters