11.7.1.2Program: Stormy Day

If
Module 'Climate' Light < 5
And Program 'Wait to Change Outside Lights' is True
Then
Run Program 'Wait to Change Outside Lights' (Else Path)
Else
- No Actions - (To add one, press 'Action')
When the sky turns dark
Only runs if sky was light during last check
This program will turn the lights off when it becomes bright again.
11.7.1.3Program: Clear Day
If
Module 'Climate' Light >= 5
And Program 'Wait to Change Outside Lights' is False
Then
Run Program 'Wait to Change Outside Lights' (Then Path)
Else
- No Actions - (To add one, press 'Action')
When the sky brightens
Only runs if sky was dark during last check
This program waits for 5 minutes so unusual Light levels are ignored. It also serves as a
Flag for the previous two programs so the Wait command is not restarted every time the
Light data changes. Only when the Light data crosses the threshold (5 in this example) is
this program restarted. This program can be in the same folder.