$sALarm.Level = 1 gives a short beep on a few buzzlincs to alert the homeowner there is
something to be looked at, and a notification should have been sent from the monitoring
program.
11.10.2.3Program: Alarm level 1
If
$sAlarm.level is 1
Then
Set 'Mudroom / MudRm Beeper' On
Set 'Utility Room / Util Beeper' On
Wait 1 second
Set 'Mudroom / MudRm Beeper' Off
Set 'Utility Room / Util Beeper' Off
$sAlarm.level = 0
Else
- No Actions - (To add one, press 'Action')
Level 1, beep, in-house only, for Low batteries, etc.
$Alarm.level = 2, longer beeper sounds to alert of more serious problems, and that
notifications were sent from sensing devices.
11.10.2.4Program: Alarm level 2
If
$sAlarm.level is 2
Then
Set 'Mudroom / MudRm Beeper' On
Set 'Utility Room / Util Beeper' On