software. For use with such applications, the first 1024 RC-5 codes (devices 0 to 15) have
been generated as both hex strings and .ccf files, and placed in the .zip file linked above.
This will make it easy for the user of such a device to simply select the required number of
codes and import them. The .zip file contains a readme file.

16.6 Adjusting IR Press/Release Delays

You can change the default settings for detecting when a hold, Release, or double press has
occurred.
16.6.1
Hold Detect
The number of milliseconds the button must be pressed before it is considered a HOLD. If
the button is released before Hold Detect milliseconds elapse, it is considered a PRESS.
The default value is 800, you can lower this value if you want HOLD to be detected quicker.
16.6.2
Hold Maintain
The number of milliseconds to wait for the next code sent by the remote.
While the remote button is being held down (HOLD), it continually sends out codes. When
the button is released, it stops sending those codes, and thus the RELEASE action is
detected.
The default value is 300, you can lower this value if you want RELEASE to be detected
sooner. Ideally, this value should be as low as possible.
Note: DOUBLE PRESS also uses the Hold Maintain value. If a button is pressed, and then
pressed again within the Hold Maintain time then it is considered a DOUBLE PRESS.
16.6.3
Change These Values
These values take effect the moment they are changed.
• Get your ISY IP address for your ISY.
• Telnet to your ISY and login with your username and password
• Use the CI command, it will prompt you for new values for Hold Detect and Hold
Maintain