11.4.2.4.6Weather Temp High Above 70 Degrees
If
Module 'Climate' Temperature High > 70 °F
Then
$Weather_Temp_High_Above_70_Degrees = 1
Else
$Weather_Temp_High_Above_70_Degrees = 0
This is in a separate program to avoid having the temperature event trigger a
false start of the irrigation system.

11.4.2.5Folder: Manual

11.4.2.5.1Any "Irrigation All" Stations On
If
Status 'Irrigation / Irrigation1 Front Plants' is not Off
Or Status 'Irrigation / Irrigation2 Empty' is not Off
Or Status 'Irrigation / Irrigation3 Back Daylilies' is not Off
Or Status 'Irrigation / Irrigation4 Back Fruit Trees' is not Off
Or Status 'Irrigation / Irrigation5 Back Maple Trees' is not Off
Or Status 'Irrigation / Irrigation6 Back Lawn1' is not Off
Or Status 'Irrigation / Irrigation7 Back Lawn2' is not Off
Or Status 'Irrigation / Irrigation8 Back Lawn3' is not Off
Page | 272