11.8.1.2Program #2 - Motion 2 – Enabled
If
Control 'Main Bath Motion.1-Sensor' is switched On
And Control 'Main Bath Motion.1-Sensor' is not switched Off
Then
Set 'Main Bath Lights' On
Else
Wait 4 minutes
Set 'Main Bath Lights' Off
Here the Wait time occurs after the motion sensor has timed out and sent the Off command,
so if the motion sensor's timer is set to the default of one minute, then the total timeout
period of this program will be five minutes.
Another improvement is to separate the on portion and the timer portion of the program,
in order to allow having the INSTEON On command sent to the light switch only when the
light is currently off, thereby reducing INSTEON traffic by not sending redundant On
commands when the light is already on:
11.8.1.3Program #3 - Main Bath Motion On – Enabled
If
Control 'Main Bath Motion.1-Sensor' is switched On
And Status 'Main Bath Lights' is not On
Then
Set Scene 'sMain Bath Lights' On
Else
- No Actions - (To add one, press 'Action')