Create a program called Leak Sensor Problem
If
(
)
And (
)
Then
Send Notification to 'Brian' content 'Leak Sensor Problem'
Else
- No Actions - (To add one, press 'Action')
Test leak sensor in "wet" mode and ensure a notification is sent

11.6.1.4Brief Explanation

The 10 second wait in Variable Control 1 serves to stop multiple emails from being
generated if the sensor "flutters" when it first activates.
The Variable Control 2 program should always be in a "Running Then" state, looking for the
heartbeat signal. If it's missed then it changes the variable to status = 2 which triggers a
notification email.
The Variable Control 3 program serves as a "watch-dog" for Variable Control 2. If it's
stopped (manually, ISY issue, etc.), then it changes the variable to status = 3 which triggers
a notification email.
The iStartUp variable is initialized to 0 on start-up and this triggers the "Leak Startup"
program to run. Without this program, the potential exists for a "dead" leak sensor to go
undetected after the ISY starts up.
Time is 9:00:00AM
Or Time is 6:00:00PM
$sLeakKitchenSink is not 1
Or $sLeakStorageRoom is not 1