I use two programs (Flag 1 and Flag 2) to keep track of the state of the timer.
One thing that I could not do is have the LED lights indicate the amount of time left on the
timer. The SwitchLinc Relay by design will only display all LEDs on or all off.
Here are the programs.
First there are 4 programs for the 4 different timer states:

9.8.2.1Program: Fan Timer on 15 Min

If
Control 'Utility Room Fan' is switched On
And (
Program 'Flag 1' is False
And Program 'Flag 2' is False
)
Then
Run Program 'Run 15 min' (Then Path)
Else
- No Actions - (To add one, press 'Action')