Processor (CPU)
Figure 204: Installing the heat sink
Ê Turn the heat sink upside down and check if all four blue washers are in
place, see figure 197.
Ensure that no screw falls out.
Ê Carefully seat the heat sink onto the CPU socket.
I
Take care of the pins. There is only one position which fits.
Ê Fasten the four captive screws in the sequence printed on the heat sink
(1 to 4) by hand, by proceeding as follows:
Torque: 1.4 Nm (not used in Japan)
Ê At first, fasten the captive screws 1 and 2 completely.
Ê Fasten the captive screws 3 and 4 completely.

11.2.4 Upgrading the main memory

Ê Select an adequate memory configuration for "2 CPUs populated", see
section
"Basic information" on page
Ê Install memory modules, see section
page
282.
296
Upgrade and Maintenance Manual
270.
"Installing a memory module" on