Upgrading The Main Memory - Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX2550 M4:
Table of Contents

Advertisement

Processor (CPU)
Ê Fasten the four captive screws in the sequence printed on the heat sink
(1 to 4) by hand, by proceeding as follows:
Torque: 1.4 Nm (not used in Japan)
Ê At first, fasten the captive screws 1 and 2 completely.
Ê Fasten the captive screws 3 and 4 completely.

11.2.4 Upgrading the main memory

Ê Select an adequate memory configuration for "2 CPUs populated", see
section
"Basic information" on page
Ê Install memory modules, see section
page
350.
11.2.5 Concluding steps
"Installing the system air duct" on page 68
Ê
"Reassembling" on page 68
Ê
"Connecting the power cord" on page 81
Ê
"Switching on the server" on page 82
Ê
I
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There is
no technical problem.
Please proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.