Upgrading The Main Memory - Fujitsu PRIMERGY RX200 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX200 S8:
Table of Contents

Advertisement

Processors
Figure 148: Installing the heat sink
Ê Align the heat sink and fit it on the processor socket.
Ê Position the screws in the holes carefully, making sure they are upright.
V
CAUTION!
– Ensure that the screws on the heat sink are properly seated on the
threaded holes.
– Ensure that the heat sink cooling fins match the direction of the
airflow!
Ê Fasten it in a crossover pattern with four screws according to the numbering
(torque 1.0 Nm, the description of this torque value doesn't apply to the
Japanese market.)

11.2.4 Upgrading the main memory

Ê Select an adequate memory configuration for "Two CPUs populated" as
described in section
Ê Install memory modules as described in section
module" on page
220
"Memory sequence" on page
205.
Upgrade and Maintenance Manual
198.
"Installing a memory
RX200 S8